1500VDC EN
PV Cable Specification
Construction and properties
The construction of wire shall be complied with following and table 1.

1) ConductorSoft annealed stranded tin-plated copper
2) InsulationElectron beam cross-linked material(XLPE)
3) JacketElectron beam cross-linked material(XLPE)
4) Applicable StandardEN50618
5) Identification MarkT脺V EN50618:2014 H1Z2Z2-K 1X**mm虏
6) Voltage test of finished cableAC 6.5KV 5min,or DC 15KV 5min No break
Construction and PropertiesTable1
ConductorJacketConductor Resistance
Area.(mm虏)Construction(mm)Stranded OD(mm)Diameter(mm)ColorMax.锛埼?KM锛?锛坅t 20鈩冿級
1.530/0.25锛坢ax.0.26)1.584.80卤0.25Black Red Blue13.7
2.549/0.25锛坢ax.0.26)2.054.95卤0.258.21
456/0.30锛坢ax.0.31)2.596.10卤0.305.09
684/0.30锛坢ax.0.31)3.427.00卤0.303.39
1077/0.40锛坢ax.0.41)4.567.20卤0.301.95
Rating voltageV1500VDC
Permissible temperature鈩?/td>-40~+120
Short circuit temperature鈩?/td>+200(at the conductor max.5sec)
Mechanical Characteristics
Highly heat resistant:-40鈩?..+90鈩?( 锛?50 hours)
-40鈩?..+105鈩?( 锛?50 hours)
-40鈩?..+120鈩?( 锛?50 hours)
Expected usable life:锛?5 years
6) RoHS/Environmental Data:RoHS-conform



1000VDC 2PFG
PV Cable Specification
Construction and properties
The construction of wire shall be complied with following and table 1.

1) ConductorSoft annealed stranded tin-plated copper
2) InsulationElectron beam cross-linked material(XLPE)
3) JacketElectron beam cross-linked material(XLPE)
4) Applicable Standard2PFG 1169/08.2007
5) Identification MarkTUV 2 PfG 1169 PV1-F 1X**mm虏 NSPV NewSun PV Technology Co.,Ltd
Construction and PropertiesTable1
ConductorJacketConductor Resistance
Area.(mm虏)Construction(mm)Stranded OD(mm)Diameter(mm)ColorMax.锛埼?KM锛?锛坅t 20鈩冿級
1.530/0.25锛坢ax.0.26)1.585.20卤0.25Black Red Blue13.7
2.549/0.25锛坢ax.0.26)2.055.40卤0.258.21
456/0.30锛坢ax.0.31)2.596.20卤0.305.09
684/0.30锛坢ax.0.31)3.427.00卤0.303.39
1084/0.40锛坢ax.0.41)4.569.00卤0.301.95
16128/0.40锛坢ax.0.41)5.6010.30卤0.301.24
25192/0.40锛坢ax.0.41)7.2512.20卤0.400.795
35276/0.40锛坢ax.0.41)8.7413.80卤0.400.565
Rating voltageVDC1000
Permissible temperature鈩?/td>-40~+120
Short circuit temperature鈩?/td>+200(at the conductor max.5sec)
Mechanical Characteristics
Highly heat resistant:-40鈩?..+90鈩?( 锛?50 hours)
-40鈩?..+105鈩?( 锛?50 hours)
-40鈩?..+120鈩?( 锛?50 hours)
Expected usable life:锛?5 years
6) RoHS/Environmental Data:RoHS-conform


2PFG 1500VDC
PV Cable Specification
Construction and properties
The construction of wire shall be complied with following and table 1.

1) ConductorSoft annealed stranded tin-plated copper
2) InsulationElectron beam cross-linked material(XLPE)
3) JacketElectron beam cross-linked material(XLPE)
4) Applicable Standard2PFG 1169/08.2007
5) Identification MarkTUV 2 PfG 1169 PV1-F 1X**mm虏 NSPV NewSun PV Technology Co.,Ltd
6) Voltage test of finished cableAC 6.5KV 5min,or DC 15KV 5min No break
Construction and PropertiesTable1
ConductorJacketConductor Resistance
Area.(mm虏)Construction(mm)Stranded OD(mm)Diameter(mm)ColorMax.锛埼?KM锛?锛坅t 20鈩冿級
1.530/0.25锛坢ax.0.26)1.584.80卤0.25Black Red Blue13.7
2.549/0.25锛坢ax.0.26)2.054.95卤0.258.21
456/0.30锛坢ax.0.31)2.596.10卤0.305.09
684/0.30锛坢ax.0.31)3.427.00卤0.303.39
1077/0.40锛坢ax.0.41)4.567.20卤0.301.95
Rating voltageV1500VDC
Permissible temperature鈩?/td>-40~+120
Short circuit temperature鈩?/td>+200(at the conductor max.5sec)
Mechanical Characteristics
Highly heat resistant:-40鈩?..+90鈩?( 锛?50 hours)
-40鈩?..+105鈩?( 锛?50 hours)
-40鈩?..+120鈩?( 锛?50 hours)
Expected usable life:锛?5 years
6) RoHS/Environmental Data:RoHS-conform

Buy Solar Cable Harness
website:http://www.newsunpv.com/solar-cable-harness/

Share